Page view 6
DryAire Systems 6
Pool Heater
Pool Filter
Pool
Heater
Pool Pump
Aux.
Heater
Aux.
Heater
Pool
Filter
Pool
Pump
TOP VIEW MECHANICAL ROOM
SIDE VIEW MECHANICAL ROOM
9’
7’
10’
1
.4.1 Location and Space Requirements for Mechanical Room
As a general guide, a DRY-10, DRY-20, DRY-25, DRY-30 dehumidifier located in a
mechanical room should be installed in an area approximately 10’ long 7’ wide and 5’ or 9’
high depending on placement. This will allow sufficient room for the contractor to install
ductwork, condensate piping, aux. heat and adequate space for service.
The diagrams show below grade duct or soffit type supply duct and a single, high return
duct along with an auxiliary duct heater if needed to maintain total heating capacity at
design condition.
A dehumidifier can recover approximately 12,000 to 30,000 gallons of water per year based
on the size of the pool. Water can be very expensive in some parts of the country and if
local code permits, this soft water can be returned to the pool through the inlet skimmer for
chemical and filter treatment.