Option 2--Plaster wall with no molding
If the plastered wall is to be flush with the cabinet and no molding
is used, the wood frame must be set 1/2"(13 mm) into the inside
wall.
AB C
7. Place a 3/4"(2 cm) thick by 2" (5 cm) wide wood strip on the
bottom of the opening against the inside edge.
A. Plastered wall C. Wood frame
B. Inside wall D. Louvers
Installing wood frame
1. Construct wood frame. See "Location Requirements" for
dimensions.
2. Measure outside width and height of frame to determine wall
opening dimensions.
3. Cut opening through the wall. Remove and save insulation.
NOTES:
Dimension for depth depends on wall thickness and type
of molding.
Do not block louvers in air conditioner cabinet.
Use 1" (2.5 cm) or heavier lumber for wood frame.
14 A -_
A. Outside width
B. Outside height
C. Depth
4. Apply wood preservative to the outside exposed surface.
5. Insert the frame in the wall opening. Square and level frame.
6. Attach frame securely to the wall.
8=
A. ! 7¼" (43.8 cm)
B. 2" (5 cm) wide
C. _" (2 cm) thick
D. Indoor side of wall opening
Center the tray back in the opening and align it with the inside
edge of the opening. Using the 2 inside screw holes in the
tray back, mark screw locations for mounting the
SMART-MOUNT TM tray.
A. Flush with inside wall
g=
A. Inside screw holes
B. Indoor side of wall opening
Remove the tray back. Using these marks, drill %2" pilot holes
approximately 11/2"(3.8 cm) deep.