Optional Accessories Wiring
If it is necessary for the installer to supply additional line voltage
wiring to the inside of the furnace, the wiring must conform to all
local codes, and have a minimum temperature rating of 105°C.
All line voltage wire splices must be made inside the furnace
junction box.
The integrated control module humidifier terminals (HUM) are
energized with 115 volts whenever the induced draft blower is
energized. The integrated control module electronic air cleaner
terminals (EAC) are energized with 115 volts whenever the
circulator blower is energized.
24-Volt Humidifier
A 5" (12.7 cm) long brown wire in the wire harness at the low-fire
pressure switch provides 24 VAC humidifier control. This wire is
powered any time the pressure switch is closed. To connect
24 VAC HUM, connect the 24 VAC line of the humidifier to the 5"
(12.7 cm) brown wire. The connection can be made by either
stripping the wire and using a wire connector or by using a
field-supplied quick connect terminal. The wiring must conform
to all local and national codes. Connect the COM side of the
humidifier to the C terminal on the furnace control board (or to
the COM side of the 24 VAC transformer).
NOTE: Do not connect 115-volt humidifier to these terminals.
GAS SUPPLY AND PIPING
The furnace rating plate includes the approved furnace gas input
rating and gas types. The furnace must be equipped to operate
on the type of gas applied. This includes any conversion kits
required for alternate fuels and/or high altitude.
Inlet gas supply pressures must be maintained within the ranges
specified in the Inlet Gas Supply Pressure chart. The supply
pressure must be constant and available with all other household
gas-fired appliances operating. The minimum gas supply
pressure must be maintained to avoid unreliable ignition. The
maximum must not be exceeded to keep the furnace from
overfiring.
High Altitude Derate
When this furnace is installed at high altitude, the appropriate
high-altitude orifice kit must be applied. This is required due to
the natural reduction in the density of both the gas fuel and
combustion air as altitude increases. The kit will provide the
proper design-certified input rate within the specified altitude
range.
High altitude kits are purchased according to the installation
altitude and usage of either Natural or propane gas. Contact your
distributor for a tabular listing of appropriate altitude ranges and
corresponding manufacturer’s high altitude (Natural, propane
gas, and/or pressure switch) kits.
NOTE: Do not derate the furnace by adjusting the manifold
pressure to a lower pressure than specified on the furnace rating
plate. The combination of the lower air density and a lower
manifold pressure will prohibit the burner orifice from drawing the
proper amount of air into the burner. This may cause incomplete
combustion, flashback and possible yellow tipping.
In some areas the gas supplier may artificially derate the gas in
an effort to compensate for the effects of altitude. If the gas is
artificially derated, the appropriate orifice size must be
determined based upon the Btu/ft
3
content of the derated gas
and the altitude. Refer to the National Fuel Gas Code, NFPA 54/
ANSI Z223.1, and information provided by the gas supplier to
determine the proper orifice size.
A different pressure switch may be required at high altitude
regardless of the Btu/ft
3
content of the fuel used. Contact your
distributor for a tabular listing of appropriate altitude ranges and
corresponding manufacturer’s pressure switch kits.
Propane Gas Conversion
This furnace is configured for Natural gas. The appropriate
manufacturer’s propane gas conversion kit must be applied for
propane gas installations. Refer to “Propane Gas and/or High
Altitude Installations” section for details.
Contact your distributor for a tabular listing of appropriate
manufacturer’s kits for propane gas and/or high-altitude
installations. The indicated kits must be used to ensure safe and
proper furnace operation. All conversions must be performed by
a qualified installer or service agency.
15-Circuit Connector
Integrated Control Module
Humidifier
Electronic
Air Cleaner
Goodman 61
To prevent unreliable operation or equipment damage,
the inlet gas supply pressure must be as specified on the
unit rating plate with all other household gas-fired
appliances operating.
CAUTION
Inlet Gas Supply Pressure
Natural gas 5.0" W.C. minimum; 10.0" W.C. maximum
Propane gas 11.0" W.C. minimum; 13.0" W.C. maximum
Goodman 52
Possible property damage, personal injury or death may
occur if the correct conversion kits are not installed. The
appropriate kits must be applied to ensure safe and proper
furnace operation. All conversions must be performed by
a qualified installer or service agency.
WARNING