  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
28
AMD 383 - AMD 384
1. Power cord 3×6 mm
2
(H07RN-F)
2. Power cord 3×1.5mm
2
(H05RW-F)
3. Twisted-pair
Rated parameter and side for fuse
Position and Method of Installing Wire Controller
1. One end of the control wire of the manual controller is connected with main board of electric box of
indoor unit inside, it should be tightened by wire clamp, the other end should be connected with the
manual controller (installation sketch map as shown in below). The control wire be used for the indoor
unit and manual controller, which is the special communication wire, the length is 8 meters, the
material be adopted for the control wire should be metallic substance. The manual controller could not
be disassembled and the communication wire be used for the manual controller should not be changed
by users optionally, the installation and maintenance should be carried out by the professional
personnel.
2. First select an installation position. According to the size of the communication line of the wire
controller, leave a recess or an embedded wire hole to bury the communication line.
3. If the communication line between the wire controller (85 ×85 ×16) and the indoor unit is surface-
mounted, use 1# PVC pipe and make matching recess in the wall (refer to Figure 6); If concealed
installation is adopted, 1# PVC pipe can be used (Refer to Figure 7).
4. No matter if surface mounting or concealed mounting is selected, it is required to drill 2 holes (in the
same level) which distance shall be the same as the distance (60mm) of installation holes in the bottom
plate of the wire controller. Then insert a wood plug into each hole. Fix the bottom plate of the wire
controller to the wall by using the two holes. Plug the communication line onto the control panel. Lastly
install the panel of the wire controller.
1
3
2
POWER:
220-240V~
50Hz
Outdoor Unit
Indoor Unit
main board
main board
POWER:
220-240V~
50Hz
Unit Code Rated parameter Side
AMD 382
AMD 383
AMD 384
46010403 250 V, 25 A
46010023 250 V, 30 A
46010014 250 V, 3. 15 A
All the indoor
units
46010013 250 V, 5 A