Automatic Electronic Diagnostics
This water softener has a self--diagnostic function for the ele ctrical system (except input power and/or
water meter). The wa ter softener monitors electronic components and circuits for correct operation.
If a malfunction occurs, an error code appears in the display.
The troubleshooting chart shows the error codes tha t could appear, and the possible malfunctions for
each code.
While an error code appears in the display, all buttons are inoperable except the PROGRAM button.
PROGRAM remains operational so the service person can perform the Manual Advance Diagnostics,
see below, to further isolate the problem.
Manual Advance Diagnostics
Use the f ollowing procedure s to a dvance the water softener through the regeneration c ycles to check
operation.
Remove the top cover to observe cam and switch operation during valve rotation.
1. Press and hold the
DATA button until the display appears as shown here. The dY and number,
in the top part of the display, is days since the last recharge.
NOTE: If the softener is in the middle of a regeneration, the top part of the display shows the
cycle of regeneration, and minutes of the cycle remaining. If two cycle names are
flashing, the valve is in transition between the cycles.
LAST RECHARGE
WATER MANAGEMENT SYSTEM
TURBINE
switch
turbine
count
On
Fill
TIME
valve
position
minutes of cycle
remaining
WATER MANAGEMENT SYSTEM
TURBINE
2. The 3 digits, under WATER MANAGEMENT SYSTEM, indicate water meter operation as
follows:
000 (steady) = Soft water not in use, and no flow through the meter.
Open a nearby soft water faucet.
000 to 140 (continual) = Repeats display for each gallon of water passing through the meter.
NOTE: If you don’t get a reading in the display, with faucet open, pull the sensor from the
valve outlet port. Pass a small magnet back and forth in front of the sensor. If you get
a reading in the display with the magnet, unhook the in and out plumbing and check
the turbine for binding.
sensor
housing
turbine
turbine
support & shaft
motor
position switch
valve outlet