Whirlpool WHES45 Troubleshooting Guide Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
water softener
cold to
water heater
optional
sediment
filter
pressure tank
well pump
city water supply
well water supply
OR
Figure 1
Air Gap Requirements
A drain is needed for regeneration discharge water. A floor drain, close to the water softener, is
preferred. A laundry tub, standpipe, etc., are other drain options. Secure valve drain hose in place.
standpipe
1---1/2”
airgap
drain
hose
1---1/2”
airgap
drain
hose
laundry tubfloor drain
drain
hose
1---1/2”
airgap
Figure 2
Valve Drain Requirements
Use the flexible drain hose, that is included, measure and cut to the length needed. Flexible drain hose
is not allowed in all localities (check your plumbing codes). If local codes do not allow use of a flexible
drain hose, a rigid valve drain run must be used. Buy a compression fitting (1/4 NPT x 1/2 in. minimum
tube) and 1/2” tubing from your local hardwar e store. Then plumb a rigid drain as needed (see Figure
3).
NOTE: Avoid long drain hose runs, or elevating the hose more than 8’ above the floor. Make
the water softener valve drain as short and direct as possible.
1/4” NPT thread
Barbs for 3/8”
I.D. tubing
1/4” NPT thread
barbs
1/2” outside
diameter copper
tube (not provided)
Clip
Cut barbs from valve drain
elbow (pull clip and remove
drain valve elbow from valve)
Compression fitting
1/4 NPT x 1/2” O.D.
tube (not provided)
Hose clamp
Drain hose
Figure 3