34
No furnace
operation.
Integrated
control module
LED display
provides “E5”
error code.
E5
Open fuse. Short in low voltage
wiring.
Locate and correct
short in low voltage
wiring.
Turn off power prior to
repair.
Replace fuse with 3A
automotive fuse.
Furnace not
operating.
Integrated
control module
LED display
provides “E6”
error code.
E6
Flame sense
microamp signal
is low.
Flame sensor is
coated/oxidized.
Flame sensor
incorrectly
positioned in
burner flame.
Lazy burner flame
due to improper
gas pressure or
combustion air.
Sand flame sensor if
coated/oxidized.
Inspect for proper
sensor alignment.
Check inlet air piping
for blockage, proper
length, elbows and
termination.
Compare current gas
pressure to rating plate
info. Adjust as needed.
Turn off power prior to
repair.
Sand flame sensor
with emery cloth.
See “Vent/Flue Pipe
section for piping
details.
See rating plate for
proper gas pressure.
Furnace
operating on
low stage gas
with high stage
induced draft
blower
High stage
circulator
blower
(temperature, of
conditioned air,
lower than
typical).
Integrated
control module
LED display
provides “E7”
error code.
E7
Problem with
igniter circuit.
Improperly
connected igniter.
Shorted igniter.
Poor unit ground.
Igniter relay fault on
integrated control
module.
Check and correct
wiring from integrated
control module to
igniter.
Replace shorted
igniter.
Check and correct
furnace ground wiring.
Check igniter output
from control. Replace,
if necessary.
Turn off power prior to
repair.
Replace igniter with
correct replacement
part.
Replace control with
correct replacement
part.
Furnace fails to
operate on high
stage. Furnace
operates
normally on low
stage.
Integrated
control module
LED display
provides “E8”
error code.
E8
High-stage
pressure switch
circuit is closed
at start of
heating cycle.
Induced draft
blower is
operating.
Furnace is
operating on
low stage only.
High-stage
pressure switch
contacts sticking.
Shorts in pressure
switch circuit
wiring.
Replace high-stage
pressure switch.
Repair short in wiring.
Turn off power prior to
repair.
Replace pressure
switch with correct
replacement part.
Symptoms of
Abnormal
Operation
Diagnostic/
Status LED
Code Fault Description Possible Causes Corrective Actions Notes and Cautions
Page view 33