Whirlpool WPIO-369B Instruction Manual Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
35
Furnace fails to
operate on high
stage. Furnace
operates
normally on low
stage.
Integrated
control module
LED display
provides “E9”
error code.
E9
High-stage
pressure switch
circuit is not
closed.
Induced draft
blower is
operating.
Furnace is
operating on
low stage only.
Pressure switch
hose blocked,
pinched or
connected
improperly.
Blocked flue and/or
inlet air pipe,
blocked drain
system or weak
induced draft
blower.
Incorrect pressure
switch setpoint or
malfunctioning
switch contacts.
Loose or
improperly
connected wiring.
Inspect pressure
switch hose. Repair, if
necessary.
Inspect flue and/or
inlet air piping for
blockage, proper
length, elbows and
termination.
Check drain system.
Correct as necessary.
Check induced draft
blower performance.
Correct as necessary.
Correct pressure
switch setpoint or
contact motion.
Tighten or correct
wiring connection.
Turn off power prior to
repair.
Replace pressure
switch with correct
replacement part.
Replace induced draft
blower with correct
replacement part.
Furnace fails to
operate.
Integrated
control module
LED display
provides “EA”
error code.
EA
Polarity of
115-volt AC is
reversed.
Polarity of 115-volt
AC power to
furnace or
integrated module
is reversed.
Poor furnace
ground.
Review wiring diagram
to correct polarity.
Verify proper ground.
Correct if necessary.
Check and correct
wiring.
Turn off power prior to
repair.
Furnace fails to
operate.
Integrated
control module
LED display
provides “d0
error code.
d0
Data not yet on
network.
Furnace does not
contain any shared
data.
Populate shared data
set using memory
card.
Turn off power prior to
repair.
Use memory card for
the specific model.
Insert memory card
before turning on
power. Memory card
may be removed after
data is loaded.
Turn off power before
removing memory
card.
Error code will be
cleared once data is
loaded.
Operation
different than
expected or no
operation.
Integrated
control module
LED display
provides “d4
error code.
d4
Invalid memory
card data.
Shared data set on
memory card has
been rejected by
integrated control
module.
Verify shared data set
is correct for the
specific model.
Repopulate data using
correct memory card, if
required.
Turn off power prior to
repair.
Use memory card for
the specific model.
Insert memory card
before turning on
power. Memory card
may be removed after
data is loaded.
Turn off power before
removing memory
card.
Error code will be
cleared once data is
loaded.
Symptoms of
Abnormal
Operation
Diagnostic/
Status LED
Code Fault Description Possible Causes Corrective Actions Notes and Cautions
Page view 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40

Comments to this Manuals

No comments