DIP Switch Chart
Switch DIP Switch Number
Bank Purpose Function 1 2 3 4 5 6 7 8 9 10
S1 Heat Off
Delay
90 Seconds Off Off --- --- --- --- --- --- --- ---
120 Seconds On Off
--- --- --- --- --- --- --- ---
150 Seconds* Off On
--- --- --- --- --- --- --- ---
180 Seconds On On
--- --- --- --- --- --- --- ---
Thermostat
Setup
1-Stage T-Stat
--- --- Off --- --- --- --- --- --- ---
2-Stage T-Stat
--- --- On --- --- --- --- --- --- ---
5-Min Delay --- --- --- Off --- --- --- --- --- ---
Auto Delay
--- --- --- On --- --- --- --- --- ---
S2 Bus BIAS BIAS On* On*
--- --- --- --- --- --- --- ---
TERM Bus Termination --- --- On* --- --- --- --- --- --- ---
S3 Cooling
Speed Tap
AOffOff
--- --- --- --- --- --- --- ---
BOnOff
--- --- --- --- --- --- --- ---
COffOn--- --- --- --- --- --- --- ---
D* On On
--- --- --- --- --- --- --- ---
Adjust Taps Normal*
--- --- Off Off --- --- --- --- --- ---
10% --- --- On Off --- --- --- --- --- ---
-10%
--- --- Off On --- --- --- --- --- ---
Normal
--- --- On On --- --- --- --- --- ---
S4 Ramping
Profiles
A*
--- --- --- --- Off Off --- --- --- ---
B
--- --- --- --- On Off --- --- --- ---
C
--- --- --- --- Off On --- --- --- ---
D
--- --- --- --- On On --- --- --- ---
Heating
Speed Tap
A
--- --- --- --- --- --- Off Off --- ---
B*
--- --- --- --- --- --- On Off --- ---
C --- --- --- --- --- --- Off On --- ---
D
--- --- --- --- --- --- On On --- ---
S5 DEHUM Disabled*
--- --- --- --- --- --- --- --- Off Unused
Enabled
--- --- --- --- --- --- --- --- On Unused