37
■ Furnace fails to
operate.
■ Integrated
control module
LED display
provides “b4”
error code.
b4
■ Circulator
blower motor
senses a loss of
rotor control.
■ Circulator
blower motor
senses high
current.
■ Abnormal motor
loading, sudden
change in speed or
torque, sudden
blockage of
furnace air inlet or
outlet.
■ High loading
conditions, blocked
filters, very
restrictive
ductwork,
blockage of
furnace air inlet or
outlet.
■ Check filters, filter
grills/registers, duct
system and furnace air
inlet/outlet for
blockages.
■ Turn off power prior to
repair.
■ Furnace fails to
operate.
■ Integrated
control module
LED display
provides “b5”
error code.
b5
■ Circulator
blower motor
fails to start
10 consecutive
times.
■ Obstruction in
circulator blower
housing.
■ Seized circulator
blower motor
bearings.
■ Failed circulator
blower motor.
■ Check circulator
blower for
obstructions. Remove
and repair/replace
wheel/motor, if
necessary.
■ Check circulator
blower motor shaft
rotation and motor.
Replace motor if
necessary.
■ Turn off power prior to
repair.
■ Replace motor with
correct replacement
part.
■ Replace wheel with
correct replacement
part.
■ Furnace fails to
operate.
■ Integrated
control module
LED display
provides “b6”
error code.
b6
■ Circulator
blower motor
shuts down for
over or under
voltage
condition.
■ Circulator
blower motor
shuts down due
to over
temperature
condition on
power module.
■ High AC line
voltage to furnace.
■ Low AC line
voltage to furnace.
■ High ambient
temperatures.
■ Check power to
furnace. Verify line
voltage to furnace is
within the range
specified on the
furnace rating plate.
■ See “Product
Description” and
“Location
Requirements and
Considerations” for
furnace installation
requirements.
■ Turn off power prior to
repair.
■ Furnace fails to
operate.
■ Integrated
control module
LED display
provides “b7”
error code.
b7
■ Circulator
blower motor
does not have
enough
information to
operate
properly.
■ Motor fails
to start
40 consecutive
times.
■ Error with
integrated control
module.
■ Motor has a locked
rotor condition.
■ Check integrated
control module. Verify
control is populated
with correct shared
data set. See data
errors above for
details.
■ Check for locked rotor
condition (see error
code above for
details).
■ Turn off power prior to
repair.
■ Replace with correct
replacement part(s).
■ Use memory card for
the specific model.
■ Furnace
operates at
reduced
performance or
operates on low
stage when
high stage is
expected.
■ Integrated
control module
LED display
provides “b9”
error code.
b9
■ Airflow is lower
than demanded.
■ Blocked filters.
■ Restrictive
ductwork.
■ Undersized
ductwork.
■ Check filters for
blockage. Clean filters
or remove obstruction.
■ Check ductwork for
blockage. Remove
obstruction. Verify all
registers are fully open.
■ Verify ductwork is
appropriately sized for
system. Resize/replace
ductwork if necessary.
■ Turn off power prior to
repair.
Symptoms of
Abnormal
Operation
Diagnostic/
Status LED
Code Fault Description Possible Causes Corrective Actions Notes and Cautions