REFRIGERATION FLOW DIAGRAM
27 DryAire Systems
DEHUMIDIFIER ONLY [Fig. 1]
The DryAire dehumidifier installed by itself will always
discharge warm dry air back to the room. The dis-
charge air temperature will be approximately 10°F to
20°F above the inlet air temperature. The moisture
content of the air will also contribute to the tempera-
ture rise.
If the discharge of warm supply air becomes a con-
cern, especially during summer months, we recom-
mend an optional Remote Outdoor Condenser that
properly matches the system.
REMOTE OUTDOOR
AIR-COOLED CONDENSER
[Fig. 2-3]
The addition of a DryAire remote outdoor condenser
will transform the dehumidifier into an air conditioner
and allow cool dry air to discharge back into the
room. The cool dry discharge air temp will be approx-
imately 10°F to 20°F below the inlet air temperature.
This function is controlled by an automatic change
over thermostat.
SYSTEM DESIGN
When the DryAire de-humidistat control calls for
dehumidification, the thermostat monitors the room
temperature; if the temperature is above the set-
point, the changeover thermostat will automatically
switch to cooling mode.
An electronically operated solenoid valve will divert
the flow of refrigerant from the internal condenser in
the dehumidifier to the outdoor remote condenser,
allowing the dehumidifier to discharge cool dry air
into the room.
When the thermostat is satisfied and the room tem-
perature falls below the heating setpoint, the thermo-
stat will automatically call for heat and the solenoid
valve will divert the refrigerant back to the internal
condenser located in the dehumidifier and discharge
warm dry air.
Page view 27