SERVICEABLE ELECTRICAL COMPONENTS
SERVICEABLE PARTS
COMPRESSOR
Run Winding
Start Winding
RELAY
OVERLOAD
WATER RECIRC. PUMP
WATER VALVE
(.31 gpm)
SOLENOID COIL (HGV)
THERMISTOR (Bin)
THERMISTOR (Evap)
PC BOARD
TRANSFORMER
COND. FAN MOTOR
DRAIN PUMP (optional)
Part No.
2176659
2183410
2183404
2185748
2185531
759112
2185679
2185680
2185621
2185657
2183437
2185528
Wattage
244
26 - 30
12 nom.
7 - 9
23
40
12 - 15
Resistance
1 - 5
3 - 11
15.95
277.5
376
10K@ 77°F (25°C)
10K@77°F (25°C)
360
277 - 275
6.9
SERVICING INFORMATION
1. Refrigerant charge must be applied to the high side only.
2. This unit operates on 120 VAC except for the cutter grid, electronic control board and optional
light, which operate at 8.7 VAC.
3. The transformer, cutter grid and electronic control board remain energized in ON and CLEAN
modes.
THERMISTOR OPERATING PARAMETERS
EVAPORATOR THERMISTOR
ICE THICKNESS
NORMAL
THICK
THIN
CUT-IN
CUT-OUT
WATER VALVE OFF (during harvest)
Temperature
52.5°F ± .3°
52.5°F ± .3°
52.5°F ± .3°
Resistance
18.7k
± 1%
18.7k
± 1%
18.7k
± 1%
Temperature
6.5°F ± .3°
4.5°F ± .3°
8.5°F ± .3°
Resistance
69.3k
± 1%
73.5k
± 1%
65.3k
± 1%
Temperature
40°F ± .3°
40°F ± .3°
40°F ± .3°
Resistance
25.9k
± 1%
25.9k
± 1%
25.9k
± 1%
ICE BIN THERMISTOR
BIN SHUT-OFF
Temperature
40°F ± 1°
Resistance
25.9k
± 3%
Temperature
35°F ± 1°
Resistance
29.8k
± 3%
If evaporator thermistor is not present or open, the electronic control will continue to make ice based